Applica! on Type 10: Volume of horizontal oval tank
(measurement result in register 30303-30304)
Register Func! on Value Range
40402 Applica! on Type 10
40403 Volume Units 1 to 7
40404 Decimal Place 0 to 3
40405 Max Distance ≥ Empty Distance
40406 Full Distance Typically = Blanking Distance
40407 Empty Distance 0 to 10364 mm
40436-40437 Tank Length 0 to 100,000 mm
40438-40439 Tank Depth 0 to 100,000 mm
40440-40441 Tank Width 0 to 100,000 mm